The Jem Hydra is a multi-headed fog generator which gives you total flexibility in fog placement through a maximum of 16 individually DMX controlled output heads, all serviced by one centralized base. |
Features |
---|
|
Tech Specs |
Physical Head Length: 440 mm (17.4 in.) Width: 392 mm (15.5 in.) Height: 167 mm (6.6 in.) Dry Weight: 13.8 kg (30.5 lbs.) Base Length: 664 mm (26.2 in.) Width: 392 mm (15.5 in.) Height: 939 mm (37.0 in.) Dry weight: 35 kg (77.2 lbs.) incl. two empty 25 l drums Performance Max. fog output (approx.): 700 m3 per minute per head Max. operating time at full output (approx.): 60 minutes (full 16-head system) Operating time: Continuous, automatic level adjustment Warm-up time (approx.): 9 minutes Control and Programming Control options: Onboard control panel, DMX Instant or timer-controlled variable output Output is proportional for all levels above 12% DMX channels: 1 per head, maximum 16 Protocol: USITT DMX512/1990 Optional digital remote control: For limited control Construction Housing: Steel & aluminum Heat exchanger: 1500 W, direct thermal protection Fluid System Fluid pump: Low pressure pump in Base Unit supplies constant 2.5 bar pressure Pump (EP5) in Head Unit increases 2.5 bar inlet pressure to 16 bar Solenoid valve in Head Unit for instant cut-off Onboard fluid capacity: 2 x 25 l Fluid consumption at peak output: 120 ml per minute per head Installation Orientation (Head): Any Orientation (Base): Floor mount only (On wheels) Connections DMX data: 3-pin and 5-pin XLR sockets Remote control: 3-pin locking XLR Power cable entry (Base): 3-pin IEC male socket Power cable entry (Head): Hard-wired Electrical AC power (EU models): 220-240 V nominal, 50 Hz AC power (US models): 110-120 V nominal, 60 Hz Main fuse (220-240 V power), Head Unit: 10 A Main fuse (110-120 V power), Head Unit: 15 A Main fuse (220-240 V power), Base Unit: 3.15 AT (slow blow) Main fuse (110-120 V power), Base Unit: 6.3 AT (slow blow) Typical Power and Current Head Unit US model 110 V, 60 Hz: 1093 W, 9.93 A 115 V, 60 Hz: 1195 W, 10.4 A 120 V, 60 Hz: 1301 W, 10.84 A EU model 220 V, 50 Hz: 1361 W, 6.18 A 230 V, 50 Hz: 1488 W, 6.47 A 240 V, 50 Hz: 1620 W, 6.8 A Measurements made at nominal voltage. Allow for a deviation of +/- 10%. Base Unit US model 110 V, 60 Hz: 228 W, 2.07 A 115 V, 60 Hz: 250 W, 2.17 A 120 V, 60 Hz: 272 W, 2.27 A EU model 220 V, 50 Hz: 210 W, 0.95 A 230 V, 50 Hz: 229 W, 1 A 240 V, 50 Hz: 250 W, 1.04 A Measurements made at nominal voltage. Allow for a deviation of +/- 10%. Thermal Maximum ambient temperature (Ta max.): 40° C Exterior surface temperature, steady state: 50° C Max. nozzle temperature: 200° C Approvals EU safety: EN 50 081-1, EN 50 082-1 EU safety: EN 60 335-1 (1995) CE Included Items Hard wired mains cable 2 m (head) M8 x 13 mm safety eye (head): P/N 08131901 Fluid line 'tee' piece 10 mm x 10 mm x 6 mm (head): P/N 26460790 Fluid line 6 mm x 10 m (head): P/N 62520020 Container 25 l (x2): P/N 34300529 Fluid line 10 mm x 30 m (x2): P/N 14026021 Power cable 1.5 m IEC w/o end plug: P/N 11501012 Blanking plug 10 mm push In: P/N 26460740 Terminator, 3 pin male hydra: P/N 56250080 Terminator, 3 pin female hydra: P/N 56250090 User manual: P/N 35000194 Accessories Pro Smoke Super (ZR Mix) fluid Pro Smoke High Density (SP Mix) fluid Regular DJ (DJ mix) fluid Pro Steam Simulation (AA) fluid I-fog fluid Digital Multi-function Remote Control: P/N 92765026 Hydra Termination Plug (Male): P/N 56250080 Hydra Termination Plug (Female): P/N 56250090 Self-seal connector, 2 x 6 mm m/f, valved: P/N 92620007 Self-seal connector, 2 x 10 mm m/f, valved: P/N 92620008 30 m length of 10 mm tubing: P/N 92620010 Straight-through connector, 2 x 10 mm: P/N 92620009 Ordering Information Jem Hydra Base Unit, 110 V: P/N 92250300 Jem Hydra Base Unit, 240 V: P/N 92250200 Jem Hydra Head Unit, 110 V: P/N 92250500 Jem Hydra Head Unit, 240 V: P/N 92250400 |